DPSI BUS HUB
Contents
Product description
The DPSI BUS HUB is a digital bus distribution module which can handle common sum signals. It is equipped with the connectors and can be extended if desired. The DPSI BUS HUB ensures connections of approx. ten bus servos without soldering. The servos can be connected with the HUB-2 and HUB-3 plug system or with latching Bus wing plugs and sockets to the DPSI BUS HUB.
Connections and wiring
Wing wiring
The connection to the wings is made with 12in long silicon cables with latching wing plugs. For thin wing profiles inside the wings the Bus wing plugs for 2 or 3 servos can be used. With thick wing profiles alternatively the Bus wing cable with plug can be used. Then servo connection is made with Servo SinglePorts.
Fuselage wiring
Servos inside the fuseslage's backside can be connected to a 47in integrated HUB-2 cable. Further servos can be connected with additional BUS HUB-2 or BUS HUB-3 cables.
Connections diagram
Connector | Description |
---|---|
1 | Bus connection cable with sockets to connect wing plugs |
2 | Hub2 bus cable to connect bus servos |
Optional dual power supply and regulated input voltage
The DPSI BUS HUB can be operated with the listed DPSI dual power supplies:
- DPSI Micro DualBat series
- DPSI Ampere optionally with or without voltage regulator DPSI Voltage
Dual power supply with the DPSI Micro DualBat
For operating the DPSI BUS HUB with a DPSI Micro DualBat and two monitored batteries two batteries must be connected to the battery inputs "Bat.1" and "Bat.2" of the DPSI Micro DualBat. The DPSI Micro DualBat dual power supply must be connected with the "RV OUT" output to the DPSI BUS HUB input "BAT".
The listed DPSI Bicro DualBat dual power Supplies are suitable for operating the DPSI BUS HUB:
- DPSI Mirco DualBat 5.5V/5.9V MPX-1xMPX
- DPSI Mirco DualBat 5.9V/7.2V MPX-1xMPX
In addition to the safety-related dual power supply the DPSI Micro DualBat allows operating with a regulated input voltage of 5.5 volts, 5.9 volts or 7.2 volts. The DPSI BUS HUB can be switched on and off with the magnetic switch integrated inside the DPSI Micro DualBat.
Dual power supply with the DPSI Ampere
For operating the DPSI BUS HUB with a DPSI Ampere and two monitored batteries two batteries must be connected to the battery inputs "Battery 1" and "Battery 2" of the DPSI Ampere. The DPSI Micro DualBat dual power supply must be connected with the "Vout" output to the DPSI BUS HUB input "BAT".
In addition to the safety-related dual power supply the DPSI Ampere allows switching on and off the DPSI BUS HUB with the magnetic switch integrated inside the DPSI Ampere.
If an additional voltage regulation is needed optionally the voltage regulator DPSI Voltage can be used. The DPSI Voltage must be connected to the DPSI Ampere's "Vout" and "Charge" connectors, the DPSI Voltage's "Reg. out" output must be connecetd to teh DPSI BUS HUB's "BAT" input. With the jumper "Reg. out" a regulated input voltage of 6.0 volts, 6.6 volts or 7.2 volts can be selected.
Specifications
Input voltage | 6V - 8.4V (5 NiMH or 2S Li++) |
Output voltage (regulated for RX output) | 5.9V |
Ampacity (RX output) | Permanent 2A, Peak 10A @ 2S LiPo battery |
Output voltage (unregulated for servos) | Identical to the input voltage |
Ampacity (unregulated output) | Permanent 8A, Peak 16A |
Power-on control | LED |
Quiescent current | approx. 3.5mA @ 7.4V |
Max. amount servos | 10 |
Dimensions | 50mm x 39mm x 14mm |
Weight | approx. 86 Gramm |