==Product description== | ==Product description== | ||
− | [[File:DPSI-Micro- | + | [[File:DPSI-Micro-5.9-7.2 JR Gesamt 640x400.jpg|thumb|left]] |
− | + | Compact LiPo regulator with magnetic switch and regulated output voltage for 5/6cell NiCd/NiMH as well as LiIon/LiPo and LiFePo4 batteries. Regulated and stabilized output voltage 5.5V/5.9V or 5.9V/7.2V adjustable. | |
Dual electronically On/Off-switch for complete contact less switching operation with an external magnet from outside. | Dual electronically On/Off-switch for complete contact less switching operation with an external magnet from outside. | ||
Line 13: | Line 13: | ||
<br> | <br> | ||
<br> | <br> | ||
+ | |||
+ | ==Features== | ||
+ | {| class="wikitable" | ||
+ | |+align="bottom"|''Features DPSI Micro SingleBat'' | ||
+ | |- | ||
+ | !Feature | ||
+ | !implemented | ||
+ | |- | ||
+ | |[[Electronic switch]] | ||
+ | |<span style="background-color:#66cdaa">Yes</span> | ||
+ | |- | ||
+ | |[[Dual power supply]] | ||
+ | |<span style="background-color:#f08080">No</span> | ||
+ | |- | ||
+ | |Voltage regulator | ||
+ | |<span style="background-color:#66cdaa">Yes</span> | ||
+ | |- | ||
+ | |[[Servo current distribution]] | ||
+ | |<span style="background-color:#f08080">No</span> | ||
+ | |- | ||
+ | |[[Servo signal distribution]] | ||
+ | |<span style="background-color:#f08080">No</span> | ||
+ | |} | ||
==Versions== | ==Versions== | ||
Line 26: | Line 49: | ||
<gallery> | <gallery> | ||
− | File:DPSI-Micro | + | File:DPSI-Micro-5.9-7.2 JR Anschlüsse 640x400.jpg|JR battery connection |
− | File:DPSI-Micro | + | File:DPSI-Micro-5.5-5.9 MPX Anschlüsse 640x400.jpg|MPX battery connection |
</gallery> | </gallery> | ||
==Delivery contents== | ==Delivery contents== | ||
− | DPSI Micro SingleBat, | + | DPSI Micro SingleBat, switching magnet with EMCOTEC tag, screws, screwing collar, drilling template, vibration protection, quick reference guide |
− | + | <!--Template DPSI Micro mounting suggestions--> | |
− | + | {{DPSI Micro mounting suggestion EN}} | |
− | <!-- | ||
− | |||
− | + | ==Operating== | |
+ | ===Output voltage selection=== | ||
+ | [[File:DPSI-Micro-SingleBat Spannungswahlschalter 640x400.jpg|thumb|left|Voltage selector DPSI Micro SingleBat]] | ||
+ | The output voltage of the DPSI Micro can be selected in two steps: 5.5V/5.9V or 5.9V/7.2V. This can be done by selecting the desired voltage with the voltage selector. | ||
+ | |||
+ | Some servos are only approved for 4.8 volts according to their manufacturer's specifications (e.g. fast tail rotor servos for helicopters). Here, an output voltage of 5.5 volts is simply allowable. The manufacturer's values refer to 4-cell NiCad batteries. When fully charged, these batteries carry up to 5.5 volts, too. 4.8 volts are reached, when these batteries are almost discharged. | ||
+ | |||
+ | <div class="hint">Hint: Please see specifications of your receiver and servos.</div> | ||
+ | |||
+ | <div class="hint">The higher the difference between input and output voltage, the higher the power dissipation, which is converted to heat. In models with many servos it is advisable to select the higher output voltage at the DPSI Micro to limit the power dissipation.</div> | ||
+ | |||
+ | <div class="caution">Due to drop out loss in the voltage regulation stages of the DPSI Micro systems, usage of 4-cell battery packs (NiCad / NiMH) is definitely NOT possible and is not permitted!</div> | ||
+ | |||
+ | {| class="wikitable" | ||
+ | |+align="bottom"|''Table 3: Recommended output voltage'' | ||
+ | |- | ||
+ | !Application | ||
+ | !Recommended output voltage | ||
+ | |- | ||
+ | |Tail rotor servos, helicopters with quick gyros, servos for 4.8V according to manufacturer's specification | ||
+ | |5.5V | ||
+ | |- | ||
+ | |Gliders, small motorized models with up to approx. 5 servos | ||
+ | |5.5V oder 5.9V | ||
+ | |- | ||
+ | |Aerobatic models, jets, models with more than 5 servos | ||
+ | |5.9V | ||
+ | |- | ||
+ | |Competition models (motorized aerobatic flights) | ||
+ | |5.9V | ||
+ | |} | ||
− | + | ===Switching on and off=== | |
+ | [[File:DPSI-Micro-SingleBat Schaltpositionen 640x400.jpg|thumb|left|Switching on and off position]] | ||
+ | For switching on the DPSI Micro the included magnet must be placed over the switching on position (ON) for approx. one second. The magnet can be placed in a distance up to 8 millimeters. After switching on the selected battery type is indicated by a blink code (see table 2: Blink codes/Battery types) | ||
− | + | For switching off the DPSI Micro the magnet must be placed over the switching off position (OFF) for approx. two seconds. The distance can be also up to 8 millimeters. | |
− | + | The LED goes off and the receiver system is currentless. | |
− | + | <br> | |
− | + | <br> | |
− | < | + | <br> |
+ | <br> | ||
==Batteries== | ==Batteries== | ||
Line 79: | Line 133: | ||
===Battery programming=== | ===Battery programming=== | ||
− | + | Because DPSI Micro uses intelligent voltage monitoring, the used battery type must be programmed once. The programmed type is stored in the micro controller of the DPSI Micro until eventually newly reprogrammed. | |
====Starting programming mode==== | ====Starting programming mode==== | ||
Line 91: | Line 145: | ||
Now blinking codes for the specific battery type will be shown followed by 3 seconds break (see table 3). As soon as the desired type is indicated, the programming mode must be left within 3 seconds in advance of the next blink code. Programming mode is left by putting the sliding switch back to its previous position. The selected battery type is stored. | Now blinking codes for the specific battery type will be shown followed by 3 seconds break (see table 3). As soon as the desired type is indicated, the programming mode must be left within 3 seconds in advance of the next blink code. Programming mode is left by putting the sliding switch back to its previous position. The selected battery type is stored. | ||
{| class="wikitable" | {| class="wikitable" | ||
− | |+align="bottom"|''Table | + | |+align="bottom"|''Table 2: Blink code/Battery types'' |
|- | |- | ||
!Blink code | !Blink code | ||
Line 130: | Line 184: | ||
<div class="hint">Hint: By default, battery type 2 cell LiPo battery (4x blink) is programmed at delivery.</div> | <div class="hint">Hint: By default, battery type 2 cell LiPo battery (4x blink) is programmed at delivery.</div> | ||
− | == | + | ==Error indication low voltage of battery== |
− | + | [[File:DPSI-Micro-SingleBat Fehleranzeige 640x400.jpg|thumb|left|Error indication]] | |
− | [[File:DPSI-Micro-SingleBat | + | The central LED indicates error types through blinking codes. |
− | The | ||
− | + | If the voltage of battery 1 drops below a certain value, this blinking code is output. The capacity of the battery usually suffices for one more flight before recharging is necessary. Nevertheless, the battery should be recharged anyway if this error code is displayed, assuming the correct battery type is programmed. This error code is repeated in a sequence of 6 seconds. If the error is qualified once, it stays active until turning the DPSI Micro off. | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
<br> | <br> | ||
<br> | <br> | ||
<br> | <br> | ||
<br> | <br> | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
==Specifications== | ==Specifications== | ||
{| class="wikitable" | {| class="wikitable" | ||
− | |+align="bottom"|'' | + | |+align="bottom"|''Table 4: Specifications DPSI Micro SingleBat'' |
|- | |- | ||
!Power sources | !Power sources | ||
Line 239: | Line 247: | ||
|} | |} | ||
− | == | + | ==Dimensions (Dimension drawings)== |
− | < | + | <gallery> |
+ | File:DPSI-Micro-SingleBat Masszeichnung-oben 640x400.jpg|DPSI Micro top | ||
+ | File:DPSI-Micro Masszeichnung-unten 640x400.jpg|DPSI Micro bottom | ||
+ | File:DPSI-Micro Masszeichnung-seitlich 640x400.jpg|DPSI Micro side | ||
+ | File:DPSI-Micro Masszeichnung-Stirnseite 640x400.jpg|DPSI Micro front | ||
+ | </gallery> | ||
+ | |||
+ | <!--Template Safety Hall sensor--> | ||
+ | {{Hall sensor safety note EN}} | ||
+ | |||
+ | ==Downloads== | ||
+ | ===Latest Downloads=== | ||
+ | *[https://www.hacker-motor.com/daten/anleitungen/emcotec/quickrefguide-dpsi-micro-single-bat-web.pdf Quick reference guide] | ||
+ | |||
+ | ===Download archive=== | ||
+ | *DPSI Micro SingleBat and DPSI Micro DualBat [https://www.hacker-motor.com/daten/anleitungen/emcotec/Anleitung_DPSI_Micro_V21b_DE.pdf Operating instructions German] | ||
+ | *DPSI Micro SingleBat and DPSI Micro DualBat [https://www.hacker-motor.com/daten/anleitungen/emcotec/Anleitung_DPSI_Micro_V21_EN.pdf Operating instructions English] | ||
+ | *DPSI Micro SingleBat and DPSI Micro DualBat [https://www.hacker-motor.com/daten/anleitungen/emcotec/Anleitung_DPSI_Micro_2009_FR.pdf Operating instructions French] | ||
+ | <!--Template Infobox Download archive--> | ||
+ | {{Infobox Download archive}} | ||
<!-- ==Bezugsquellen== | <!-- ==Bezugsquellen== | ||
[http://shop.rc-electronic.com/DPSI-SYSTEME/DPSI-Micro-DualBat.htm?a=catalog&p=541 DPSI Micro DualBat im iRC-Electronic-Webshop] --> | [http://shop.rc-electronic.com/DPSI-SYSTEME/DPSI-Micro-DualBat.htm?a=catalog&p=541 DPSI Micro DualBat im iRC-Electronic-Webshop] --> |
Revision as of 11:37, 9 November 2018
Contents
Product description
Compact LiPo regulator with magnetic switch and regulated output voltage for 5/6cell NiCd/NiMH as well as LiIon/LiPo and LiFePo4 batteries. Regulated and stabilized output voltage 5.5V/5.9V or 5.9V/7.2V adjustable.
Dual electronically On/Off-switch for complete contact less switching operation with an external magnet from outside.
The used battery type and the low voltage detection can be programmed. Intelligent voltage monitoring with optical error indication.
Designed for 5 up to a max. of 10 servos. Supports 4A (@5.9V), 6A (@7.2V) permanent current and 25A peak current.
Features
Feature | implemented |
---|---|
Electronic switch | Yes |
Dual power supply | No |
Voltage regulator | Yes |
Servo current distribution | No |
Servo signal distribution | No |
Versions
The versions of the DPSI Micro SingleBat differ based on the selectable output voltage (5.5V/5.9V or 5.9V/7.2V) and the battery connector plug (JR or MPX).
- DPSI Micro SingleBat 5.5V/5.9V JR
- DPSI Micro SingleBat 5.5V/5.9V MPX
- DPSI Micro SingleBat 5.9V/7.2V JR
- DPSI Micro SingleBat 5.9V/7.2V MPX
Furthermore, there is a weight-reduced version that is designed for F3A scene.
- DPSI Micro SingleBat 5.9V/7.2V F3A Edition
- DPSI-Micro-5.9-7.2 JR Anschlüsse 640x400.jpg
JR battery connection
- DPSI-Micro-5.5-5.9 MPX Anschlüsse 640x400.jpg
MPX battery connection
Delivery contents
DPSI Micro SingleBat, switching magnet with EMCOTEC tag, screws, screwing collar, drilling template, vibration protection, quick reference guide
Mounting suggestions
DPSI Micro Systems can be switched on and off contactless with an external magnet through the model's fuselage wall or with the transmitter, so they can be fixed at the fuselage inner sidewall. The switching on and off process with the magnet works up to a distance of about 8mm (0.3in) from the DPSI Micro's surface through the fuselage wall. To see the LED from the outside a small hole with 5mm (0.2in) diameter can be drilled in the fuselage wall.
Sticking on the DPSI Micro system
The DPSI Micro can be sticked on with silicone directly on the fuselage's inner sidewall.
Screwing on the DPSI Micro system
The DPSI Micro can be screwed from the outside to the fuselage wall. The required holes can be drilled using the included drilling template.
Both screws can be feed through the drilling holes from the outside. The screws are positioning helps for the self-adhesive foam rubber, which can be used as vibration protection. It is pushed over the screws from inside and glued to the fuselage's sidewall.
The DPSI Micro can be mounted with two included M3 screws. The screwing collars enlarge the area of support and inhibit in this way damage to the fuselage.
Operating
Output voltage selection
The output voltage of the DPSI Micro can be selected in two steps: 5.5V/5.9V or 5.9V/7.2V. This can be done by selecting the desired voltage with the voltage selector.
Some servos are only approved for 4.8 volts according to their manufacturer's specifications (e.g. fast tail rotor servos for helicopters). Here, an output voltage of 5.5 volts is simply allowable. The manufacturer's values refer to 4-cell NiCad batteries. When fully charged, these batteries carry up to 5.5 volts, too. 4.8 volts are reached, when these batteries are almost discharged.
Application | Recommended output voltage |
---|---|
Tail rotor servos, helicopters with quick gyros, servos for 4.8V according to manufacturer's specification | 5.5V |
Gliders, small motorized models with up to approx. 5 servos | 5.5V oder 5.9V |
Aerobatic models, jets, models with more than 5 servos | 5.9V |
Competition models (motorized aerobatic flights) | 5.9V |
Switching on and off
For switching on the DPSI Micro the included magnet must be placed over the switching on position (ON) for approx. one second. The magnet can be placed in a distance up to 8 millimeters. After switching on the selected battery type is indicated by a blink code (see table 2: Blink codes/Battery types)
For switching off the DPSI Micro the magnet must be placed over the switching off position (OFF) for approx. two seconds. The distance can be also up to 8 millimeters.
The LED goes off and the receiver system is currentless.
Batteries
Battery types
As far as batteries are concerned, commercially available types are in use: NiCad, NiMH, Lithium-Ion (LiIon) and Lithium-Polymer (LiPo). Independent of the selected output voltage, these batteries are unlimited usable. Load capability should ranch from 3C up to 10C corresponding to the application.
Battery mounting
If the battery is placed in greater distance from the DPSI Micro due to the balance point reasons and so the connection cables are long, it is usefull to twist the wires. So better interference suppression is ensured.
DPSI Micro systems are not reverse polarity protected. Please be sure that the batteries are always connected correctly. The red pole must be connected to plus the black pole to minus.
Recommended battery capacities
In general, load capability and capacity of the batteries must be observed. As far as the selection of capacities is concerned, also consider, if you want to recharge the batteries between flights or if you want to operate the model all day long without recharging.
Application | Recommended capacity |
---|---|
F3A models for competitions, small gliders with up to 5 servos | 1000mAh |
Helicopters with fast tail rotor servos | 1500mAh |
Aerobatic models and small jets with up to 7 servos | 2400mAh |
Large gliders with up to 10 servos | 3300mAh |
Battery programming
Because DPSI Micro uses intelligent voltage monitoring, the used battery type must be programmed once. The programmed type is stored in the micro controller of the DPSI Micro until eventually newly reprogrammed.
Starting programming mode
Programming starts when the voltage selector (see picture 1) is moved from one position to the other within 10 seconds of turning on.
Programming
As soon as programming mode starts, the LED is turned on for 3 seconds. Then a 3 second dark phase follows. This indicates "programming mode".
Now blinking codes for the specific battery type will be shown followed by 3 seconds break (see table 3). As soon as the desired type is indicated, the programming mode must be left within 3 seconds in advance of the next blink code. Programming mode is left by putting the sliding switch back to its previous position. The selected battery type is stored.
Blink code | Battery type | Nominal voltage |
---|---|---|
1x Blink | 5 NiCd/NiMH cells | 6.0 |
2x Blink | 6 NiCd/NiMH cells | 7.2V |
3x Blink | 2 LiIon cells | 7.2V |
4x Blink | 2 LiPo cells | 7.4V |
5x Blink | 2 LiFePO4 cells | 6.6V |
6x Blink | 7 NiCd/NiMH cells | 8.4V |
7x Blink | Deactivate tests / no error indication | --- |
If “7x blink” is selected (all tests disabled) the DPSI Micro does not monitor voltages. No empty batteries or other errors are indicated!
Error indication low voltage of battery
The central LED indicates error types through blinking codes.
If the voltage of battery 1 drops below a certain value, this blinking code is output. The capacity of the battery usually suffices for one more flight before recharging is necessary. Nevertheless, the battery should be recharged anyway if this error code is displayed, assuming the correct battery type is programmed. This error code is repeated in a sequence of 6 seconds. If the error is qualified once, it stays active until turning the DPSI Micro off.
Specifications
Power sources | 5 to 7 cell NiCd / NiMH batteries, 2 cell LiIon, LiPo, LiFePO4 batteries |
---|---|
Operating voltage | 4.8V ... 12V |
Nominal voltage | 6.0V ... 8.4V |
Output voltage | 5.5V or 5.9V respectively 5.9V or 7.2V (voltage selector) |
Quiescent current (switched off) | <1µA per battery |
Quiescent current (switched on) | approx. 90mA in total (LED on) |
Max. permanent current @ 5.9V (15 minutes with LiPo batteries) | 4A |
Max. permanent current @ 7.2V (10 minutes with LiPo batteries) | 6A |
Max. peak current @ 5.9V (10 seconds with LiPo batteries) | 10A |
Max. peak current (20ms) | 25A |
Drop out losses @ 2A | 0.5V |
CE test | according to 2004/108/EC |
Environmental conditions | -10°C ... +50°C (14°F ... 122°F) |
Permissable temperature range (Storage) | -25°C .... +85°C (77°F ... 185°F) |
Dimensions | 73,4mm x 19,4mm x 14,1mm (2.9in x 0.76in x 0.55in) |
Weight | approx. 28g (0.9oz) |
Dimensions (Dimension drawings)
Safety note
Downloads
Latest Downloads
Download archive
- DPSI Micro SingleBat and DPSI Micro DualBat Operating instructions German
- DPSI Micro SingleBat and DPSI Micro DualBat Operating instructions English
- DPSI Micro SingleBat and DPSI Micro DualBat Operating instructions French