Bevor der DPSI Fernsteuerschaltgeber (Duplex) benutzt werden kann, muss er einmalig eingerichtet werden. Hierfür muss wie folgt vorgegangen werden:
+
Before the DPSI Remote switch actuator (Duplex) can be used it must be set up once. Therefor the following procedure is necessary:
# Jeti Duplex RCSW RC-Switch an die Anlage binden '''ohne''' dass EMCOTEC RCSW Adapter angesteckt ist.
+
# Bind Jeti Duplex RCSW RC switch to the system '''without''' connected to the EMCOTEC RCSW adapter.
# Akkus an die DPSI-Doppelstromversorgung anschließen.
+
# Connect batteries to the DPSI dual power supply.
# EMCOTEC RCSW Adapter '''ohne''' den Jeti Duplex RCSW RC-Switch an den Schaltgeberanschluss der DPSI-Doppelstromversorgung anschließen. Die DPSI-Doppelstromversorgung schaltet sich automatisch ein.
+
# Connect EMCOTEC RCSW adapter to the DPSI dual power supply's switch actuator connector '''without''' the Jeti Duplex RCSW RC switch. The DPSI dual power supply switches on automatically.
# Den Jeti Duplex RCSW RC-Switch an den EMCOTEC RCSW Adapter anschließen. Die DPSI-Doppelstromversorgung schaltet sich automatisch ab (da sich der Jeti Duplex RCSW RC-Switch im "OFF"-Zustand befindet).
+
# Connect the Jeti Duplex RCSW RC switch to the EMCOTEC RCSW adapter. The DPSI dual power supply switches off automatically (due to the Jeti Duplex RCSW RC switch is in "OFF" status).
Die DPSI-Doppelstromversorgung lässt sich nun mit dem DPSI Fernsteuerschaltgeber ein- und ausschalten.
+
The DPSI dual power supply can now be switched on and off with the DPSI Remote switch actuator (Duplex).
 
+
Find details concerning connecting the DPSI Remote switch actuator (Duplex) in chapter [[#Connections|Connections]].
Informationen zum Anschließen des DPSI Fernsteuerschaltgebers (Duplex) finden Sie im Kapitel [[#Anschlüsse|Anschlüsse]].
 
  
 
<div class="hint">
 
<div class="hint">
'''Hinweise'''  
+
'''Notice'''  
 
* Im Menü des '''Jeti Duplex RCSW RC-Switch''' muss der Menüpunkt '''Invertierte Polarität''' deaktiviert sein. Der '''Jeti Duplex RCSW RC-Switch''' lässt sich sonst nicht mit dem '''EMCOTEC RCSW Adapter''' betreiben.
 
* Im Menü des '''Jeti Duplex RCSW RC-Switch''' muss der Menüpunkt '''Invertierte Polarität''' deaktiviert sein. Der '''Jeti Duplex RCSW RC-Switch''' lässt sich sonst nicht mit dem '''EMCOTEC RCSW Adapter''' betreiben.
 
* Zum Betrieb des '''DPSI Fernsteuerschaltgebers (Duplex)''' ist eine Akkuspannung von mindestens '''7 Volt''' notwendig. Bei einer niedrigeren Spannung ist der Einschaltvorgang nicht möglich. Es können daher nur Akkus verwendet werden, deren Nennspannung bei '''7,2 Volt oder 7,4 Volt''' liegt (z. B. '''LiPo- oder LiIon-Akkus).'''
 
* Zum Betrieb des '''DPSI Fernsteuerschaltgebers (Duplex)''' ist eine Akkuspannung von mindestens '''7 Volt''' notwendig. Bei einer niedrigeren Spannung ist der Einschaltvorgang nicht möglich. Es können daher nur Akkus verwendet werden, deren Nennspannung bei '''7,2 Volt oder 7,4 Volt''' liegt (z. B. '''LiPo- oder LiIon-Akkus).'''

Revision as of 09:34, 21 October 2015

Product description

DPSI Remote switch actuator (Duplex)

The DPSI Remote switch actuator (Duplex) is a switch actuator suitable for DPSI dual power supplies that can be used with Jeti Duplex systems. The DPSI Remote switch actuator (Duplex) is composed of the Jeti Duplex RCSW RC switch and the EMCOTEC RCSW adapter. Using the DPSI Remote switch actuator (Duplex) DPSI dual power supplies can be switched on and off with the transmitter.

Variants and delivery contents

The DPSI Remote switch actuator (Duplex) is composed of above-named the modules. Certainly the EMCOTEC RCSW adapter can also be purchased stand-alone when a existing Jeti Duplex RCSW RC switch should be upgraded. So the DPSI Remote switch actuator (Duplex) is available in two variants:

Table 1: Variants of the DPSI Remote switch actuator (Duplex)
Variant Description
RCSW adapter Contains a single EMCOTEC RCSW adapter for upgrading an existing Jeti Duplex RCSW RC switch.
RCSW adapter with RCSW Contains an EMCOTEC RCSW adapter and a Jeti Duplex RCSW RC switch.
Delivery contents variant RCSW adapter: 1. EMCOTEC RCSW adapter
Delivery contents variante RCSW adapter with RCSW: 1. EMCOTEC RCSW adapter, 2. Jeti Duplex RCSW RC switch


Compatibility

The DPSI Remote switch actuator (Duplex) is compatible with the listet DPSI dual power supplies:

Notice

  • The DPSI Remote switch actuator (Duplex cannot be used with the dual power supply DPSI Ampere.
  • The DPSI Remote switch actuator (Duplex) can only be used with Jeti Duplex systems. Usage with other manufacturer's systems is not possible.

First start-up

Before the DPSI Remote switch actuator (Duplex) can be used it must be set up once. Therefor the following procedure is necessary:

  1. Bind Jeti Duplex RCSW RC switch to the system without connected to the EMCOTEC RCSW adapter.
  2. Connect batteries to the DPSI dual power supply.
  3. Connect EMCOTEC RCSW adapter to the DPSI dual power supply's switch actuator connector without the Jeti Duplex RCSW RC switch. The DPSI dual power supply switches on automatically.
  4. Connect the Jeti Duplex RCSW RC switch to the EMCOTEC RCSW adapter. The DPSI dual power supply switches off automatically (due to the Jeti Duplex RCSW RC switch is in "OFF" status).

The DPSI dual power supply can now be switched on and off with the DPSI Remote switch actuator (Duplex). Find details concerning connecting the DPSI Remote switch actuator (Duplex) in chapter Connections.

Notice

  • Im Menü des Jeti Duplex RCSW RC-Switch muss der Menüpunkt Invertierte Polarität deaktiviert sein. Der Jeti Duplex RCSW RC-Switch lässt sich sonst nicht mit dem EMCOTEC RCSW Adapter betreiben.
  • Zum Betrieb des DPSI Fernsteuerschaltgebers (Duplex) ist eine Akkuspannung von mindestens 7 Volt notwendig. Bei einer niedrigeren Spannung ist der Einschaltvorgang nicht möglich. Es können daher nur Akkus verwendet werden, deren Nennspannung bei 7,2 Volt oder 7,4 Volt liegt (z. B. LiPo- oder LiIon-Akkus).

Connections

Der Jeti Duplex RCSW RC-Switch wird rechts an der Unterseite des EMCOTEC RCSW Adapters angeschlossen. Die Polung wird auf beiden Modulen angegeben. Auf dem Jeti Duplex RCSW RC-Switch muss der Anschluss Control Output benutzt werden. Der EMCOTEC RCSW Adapter wird an den Schaltgeberanschluss der entsprechenden DPSI-Akkuweiche angeschlossen.

Jeti Duplex RCSW RC-Switch an den EMCOTEC RCSW Adapter: 1. Oberseite, 2. Unterseite
Anschluss DPSI Fernsteuerschaltgeber (Duplex) z. B. an die DPSI 2018 Duplex Edition